Rack Power Distribution Unit
Description
AP7580, AP7581, AP7582, AP7583, and AP7584 are 24 A Rack Power
Distribution Units (PDUs) that provide 120- or 208-volt power to rack-
mounted equipment.
AP7580, AP7581
AP7582
28-foot NEMA L14-30 power cord
Four 20-amp circuit breakers
AP7580: Four NEMA L5-20 outlets
AP7581: Four NEMA L6-20 outlets
28-foot NEMA L14-30 power cord
Two 20-amp circuit breakers
Twelve NEMA 5-20 outlets
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - Rack Power Distribution Unit

Rack Power Distribution UnitDescriptionAP7580, AP7581, AP7582, AP7583, and AP7584 are 24 A Rack Power Distribution Units (PDUs) that provide 120- or 2

Pagina 2 - AP7583, AP7584

How to Install the PDU10 Rack Power Distribution Unit2. Choose a location for the PDU. a. Insert a caged nut (provided with the enclosure) above and b

Pagina 3 - Safety and Grounding

Rack Power Distribution Unit 11SpecificationsElectricalNominal input voltage 120 or 208 VInput frequency 50 or 60 HzInput connectors NEMA L14-30 plugO

Pagina 4 - How to Shorten the Power Cord

12 Rack Power Distribution UnitWarranty and ServiceLimited warrantyAPC warrants the PDU to be free from defects in materials and workmanship for a per

Pagina 5 - Reassemble the plug

Rack Power Distribution Unit 13Life-Support PolicyGeneral policyAmerican Power Conversion (APC) does not recommend the use of any of its products in t

Pagina 8 - Test the plug for AP7582

APC Worldwide Customer SupportCustomer support for this or any other APC product is available at no charge in any of the following ways:• Visit the AP

Pagina 9 - How to Install the PDU

2 Rack Power Distribution UnitAP7583, AP758428-foot NEMA L14-30 power cord AP7583: Four NEMA L5-30 outletsAP7584: Four NEMA L6-30 outlets

Pagina 10 - Connect to an APC UPS

Rack Power Distribution Unit 3Safety and GroundingRead the following information before installing or operating your APC Power Distribution Unit (PDU)

Pagina 11 - Specifications

4 Rack Power Distribution UnitHow to Shorten the Power CordPlug layoutRemove the plug1. Loosen, but do not remove, the four captive screws from the pl

Pagina 12 - Warranty and Service

How to Shorten the Power CordRack Power Distribution Unit 5Cut the cord1. Cut the outer cord sleeve to the desired length. Be careful not to cut throu

Pagina 13 - Life-Support Policy

How to Shorten the Power Cord6 Rack Power Distribution UnitTest the plug for AP7580 or AP7583Use a multimeter and the following graphics to verify con

Pagina 14

How to Shorten the Power CordRack Power Distribution Unit 7Test the plug for AP7581 or AP7584Use a multimeter and the following graphics to verify con

Pagina 15

How to Shorten the Power Cord8 Rack Power Distribution UnitTest the plug for AP7582Use a multimeter and the following graphics to verify continuity be

Pagina 16 - 990-1583A 10/2003

Rack Power Distribution Unit 9How to Install the PDUMounting optionsInstall the PDU in the bottom 2U of a NetShelter® or any standard 19-inch EIA-310-