Technical Specifications
96-00290-001 Rev. A1 DataDirect Networks StorageScaler 2460 User Guide | 29
Here are the technical specifications for StorageScaler 2460.
NOTE :
Specifications subject to change without notice.
A.1 General Specifications
System
2U enclosure height (rack configurations)
Up to 24 2.5" SAS or SATA disk drives (including SSD’s) per enclosure (6 Gb/sec or
3 Gb/sec)
Redundant Components
Two APC units
Up to 24 drives per enclosure
Field Replaceable Units
Disk drives and drive carrier blanks
•APC units
I/O modules
I/O module slot blanks
Enclosure Physical Dimensions
Height: 3.5" (89 mm)
Width: 17.6" (447 mm)
Depth: 19.3" (49 mm)
Weight: up to 53 lbs (27 kg) maximum (with all drives installed)
Advanced Power and Cooling (APC) Units
Input Voltage: 100–240 VAC
Current Rating: 8.40 A (max)
Input Frequency: 50/60 Hz
Outputs:
- +5 V @ 28 A
- +12 V @ 43 A
Maximum Average Output Power: 550 Watts
Cooling: Variable speed blowers, two per APC for a total of four blowers per enclosure
NOTE :
APC units are hot-swappable.