990-2689D 01/2007
User Manual
English
APC Smart-UPS
®
RT
8000/10000 VA 200-240 Vac
Tower/Rack-Mount 6U
Uninterruptible Power Supply
Vista de pagina 0
1 2 3 4 5 6 ... 20 21

Indice de contenidos

Pagina 1 - APC Smart-UPS

990-2689D 01/2007 User Manual English APC Smart-UPS® RT 8000/10000 VA 200-240 Vac Tower/Rack-Mount 6U Uninterruptible Power Supply

Pagina 2

8 Feature Function Normal /Bypass Manually switch connected equipment to bypass mode, so that utility power is sent directly to connected equipment

Pagina 3 - INSTALLATION

9 USER CONFIGURABLE ITEMS NOTE: SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE, NETWORK MANAGEMENT CARD, OPTIONAL SMART SLOT ACCESSORY

Pagina 4 - Hardwiring

10 NOTE: SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE, NETWORK MANAGEMENT CARD, OPTIONAL SMART SLOT ACCESSORY CARDS OR TERMINAL MODE. FUN

Pagina 5 - XLI MODEL

11 EPO (Emergency Power Off) Option The output power can be disabled in an emergency by closing a switch connected to the EPO. Adhere to nationa

Pagina 6

12 Terminal Mode to Configure UPS Parameters Terminal Mode is a menu driven interface that enables enhanced configuration of the UPS. Connect the se

Pagina 7

13 MAINTENANCE, SERVICE, WARRANTY, AND TRANSPORTING Replacing the Battery Module(s) This UPS has easy to replace, hot-swappable battery modules.

Pagina 8 - ASIC CONNECTORS

14 TROUBLESHOOTING Use the table below to solve minor installation and operation problems. Refer to the APC Web site, www.apc.com for assistance wit

Pagina 9 - OPERATION

15 PROBLEM AND POSSIBLE CAUSE SOLUTION BYPASS LED ILLUMINATES The bypass switch has been turned on manually or through an accessory. If bypass

Pagina 10 - On Battery Operation

16 Service If the UPS requires service do not return it to the dealer. Follow these steps: 1. Review the problems discussed in the Troubleshooting

Pagina 11 - USER CONFIGURABLE ITEMS

17 REGULATORY INFORMATION Regulatory Agency Approvals and Radio Frequency Warnings 200, 208, 220, 230, 240 V MODELS This equipment has been test

Pagina 13

18 Declaration of Conformity

Pagina 14

19 APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: •

Pagina 15 - Transporting the UPS

1 Introduction The APC Smart-UPS® RT is a high-performance, uninterruptible power supply (UPS) that provides protection for electronic equipment

Pagina 16 - TROUBLESHOOTING

2 Hardwiring Wiring must be performed by a qualified electrician. 1. Install a utility circuit breaker in accordance with local electrical codes (s

Pagina 17

3 7. XLI model only: For three-phase input, set the Input Phase Selector switch (see C) to ‘3’. For single-phase input, leave switch in default

Pagina 18 - Limited Warranty

4 Installing and Connecting the Batteries and Attaching the Front Bezel n o p q r s

Pagina 19 - REGULATORY INFORMATION

5 CONNECTING POWER AND EQUIPMENT TO THE UPS 1. Hardwire the UPS (see Hardwiring). 2. Connect equipment to the UPS (cables not included for XLT

Pagina 20 - Declaration of Conformity

6 BASIC CONNECTORS Serial Port Power management software and interface kits can be used with the UPS. Use only interface kits supplied or approved

Pagina 21

7 OPERATION FRONT DISPLAY PANEL Indicator Description Online The UPS is drawing utility power and performing double conversion to supply