APC RAID Subsystem SCSI-SATA II Manual de usuario Pagina 189

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 259
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 188
SAS / SATA II NAS System
User’s Manual
189
8.5.5 Serial Ports tab
Com1 and Com2 Serial ports can be configured in this tab for specific application. Press
"Edit".
Com1
Supported Applications are: NAS Device Mgr or proNAS HA
NOTE: This NAS model does not support NAS Device Manager. You
can use COM1 port for proNAS HA (optional) application only.
Com2
Supported Applications are: UPS or proNAS HA
If you set Com2 to UPS, you can select between two supported UPS Modes: dumb
mode or smart mode.
If you choose dumb mode, you don't have to configure the detail setting about
vendor and cable. If you choose smart mode, proNAS supports three UPS Vendor:
(a) APC, (b) BeamTech, and (c) HyperPro. Select the UPS vendor then set the UPS
Model and Cable Model. The only Beamtech UPS model supported is SSpro 650.
The only HyperPro UPS model supported is 1410HP. APC has many models supported.
APC cable models are: simple, smart, ether, usb, and snmp
Shut Down delay (Min): the time to shutdown system after power fail
SNMP IP: the IP address of APC UPS. This is enabled when cable model is set to snmp.
Auto Shutdown UPS (APC only): automatically shutdown system after power fail; APC
UPS only
After completing the settings, press "Save" button.
Vista de pagina 188
1 2 ... 184 185 186 187 188 189 190 191 192 193 194 ... 258 259

Comentarios a estos manuales

Sin comentarios